en
Low Voltage Drive:S600 Series High-performance Drives
Low Voltage Drive:S600 Series High-performance Drives

SG600 11-15kW

MOQ: 100 Pieces
Delivery time: 15 Day
1. Full drive, all-round, high-performance vector universal platform and brand new motor control algorithm. Support synchronous and asynchronous motors 2. High scalability options include PLC cards, 1/0 cards, communication cards, CAN cards, etc., which can simultaneously meet the needs of multiple expansion cards and quickly meet the personalized needs of customers. 3. Support customer secondary development
4. Support multiple mainstream communication methods, standard 485 communication 5. Comprehensive thermal simulation design to ensure the rationality of hardware layout. 6. PCB should be sprayed with three proof paint appropriately to improve product environmental adaptability.
Product Details

solar pump drive model description

The user can learn the specification from the nameplate. SG600 -2K2G- 4T   ①   ②   ③

 

 

Mark

Description

Contents

Series models

SG320,SG350,old series   SG600,new series

Drive power

7K5G stand for 7.5kw, submersible pump type     1K5G stands for 1.5kw, submersible pumps type

Voltage specification

1: = 80 to 350V DC or 110 to 220V AC input

2: = 230 to 450V DC or 200 to 240V AC   input

4: = 350 to 900V DC or 380 to 480V AC   input

S:    1 phase    input

T:    three phase input

 

3.5.Solar pump drive technical specification

 

Recommended MPPT voltage range

230~450VDC for 220VAC/240V pumps with 0.75Kw to 4kw 350~800VDC, for 380VAC pumps with1.5kw to 450kw

Recommended input voltage

310Vmp DC for 220V AC pumps, 540Vmp DC for 380V AC pumps

Motor type

Control for permanent magnet synchronous motor and asynchronous motor pumps

Maximum DC power input

1. 450VDC for 220AC output      

 2. 800VDC or 900VDC for 380V AC output

Rated output voltage

1 phase, 220V.       3 phase, 220V/380V/440V

Output frequency range

0~400Hz

MPPT efficiency

99%,

Ambient temperature range

-10~+50 C

Solar pump control special performance

MPPT ( maximum power point tracking), CVT (constant voltage

tracking), auto/manual operation, dry run protection, low stop frequency protection, minimum power input, motor maximum

current protection, flow calculating, energy generated calculating and water tank level detected, etc

Protection function

Stall protection, phase loss protection, phase short circuit

protection , ground to phase short circuit protection , input and    output short circuit protection, over-temperature protection, etc

Protection degree

IP20, Air force cooling

Running mode

MPPT or CVT

Altitude

Below 1000m; above 1000m, derated 1% for every additional 100m.

Standard

AC input backup circuit

CE, Design based on vector control drive, more specification please refer to vector control drive operation manual

3.6. Models and specification

SN

Models

Rate

current

(A)

DC input range    (VDC)

Output voltage  (VAC)

Applicable

for pumps

(KW)

Recommen

ded VOC

(VDC)

shape and size

1

SG600-0K7G-2S

4.0A

230 to 450

220 to 240

0.75KW

360 to 400

Fig.A

2

SG600-1K5G-2S

7.5A

230 to 450

220 to 240

1.5KW

360 to 400

Fig.A

3

SG600-2K2G-2S

10A

230 to 450

220 to 240

2.2KW

360 to 400

Fig.A

4

SG600-3K0G-2S

13.5A

230 to 450

220 to 240

3.0KW

360 to 400

Fig.B

5

SG600-4K0G-2S

16A

230 to 450

220 to 240

4.0KW

360 to 400

Fig.B

6

SG600-0K7GB-4T

2.5A

350 to 800

380 to 440

0.75KW

650 to700

Fig.A

7

SG600-1K5GB-4T

3.7A

350 to 800

380 to 440

1.5KW

650 to700

Fig.A

8

SG600-2K2GB-4T

5.0A

350 to 800

380 to 440

2.2KW

650 to700

Fig.A

9

SG600-4K0GB-4T

10A

350 to 800

380 to 440

4.0KW

650 to700

Fig.A

10

SG600-5K5GB-4T

13A

350 to 800

380 to 440

5.5KW

650 to700

Fig.B

11

SG600-7K5GB-4T

17A

350 to 800

380 to440

7.5KW

650 to700

Fig.B

12

SG600-011GB-4T

25A

350 to 800

380 to 440

11KW

650 to700

Fig.C

13

SG600-015GB-4T

33A

350 to 800

380 to 440

15KW

650 to700

Fig.C

14

SG600-018G-4T

38A

350 to 800

380 to 440

18.5KW

650 to700

Fig.C

15

SG600-022G-4T

45A

350 to 800

380 to 440

22KW

650 to700

Fig.C

16

SG600-030G-4T

60A

350 to 800

380 to 440

30KW

650 to700

Fig.C

17

SG600-037G-4T

75A

350 to 800

380 to 440

37KW

650 to700

Fig.C

18

SG600-045G-4T

91A

350 to 800

380 to 440

45KW

650 to700

Fig.C

19

SG600-055G-4T

110A

350 to 800

380 to 440

55KW

650 to700

Fig.C

20

SG600-075G-4T

150A

350 to 800

380 to 440

75KW

650 to700

Fig.C

21

SG600-090G-4T

180A

350 to 800

380 to 440

90KW

650 to700

Fig.C

22

SG600-110G-4T

210A

350 to 800

380 to 440

110KW

650 to700

Fig.C

23

SG600-132G-4T

250A

350 to 800

380 to 440

132KW

650 to700

Fig.C

 

VFD specifications and models

Dimension ( mm )

Mounting holes size ( mm )

Mountin

g holes (mm)

 

Size

 

Remark

W

H

D

W1

H1

d

Size

Wiring

1 PHASE 2S 220V

SG600-0K75G-2S

 

86

 

187

 

152

 

68

 

176

 

5.5

 

S1

down in down out wall mounted

SG600-1K5G-2S

SG600-2K2G-2S

SG600-3K0G-2S

105

265

164

87

252

6

S2

down in down out wall mounted

SG600-4K0G-2S

3 PHASE 4T 380V

SG600-0K75GB-4T

 

86

 

187

 

152

 

68

 

176

 

5.5

 

S1

down in down out wall mounted

SG600-1K5GB-4T

SG600-2K2GB-4T

SG600-4K0GB-4T

SG600-5K5GB-4T

105

265

164

87

252

6

S2

down in down out wall mounted

SG600-7K5GB-4T

SG600-011GB-4T

150

333

216

100

314

5.5

S3

down in down out wall mounted

SG600-015GB-4T

SG600-018G-4T

180

383

228

120

363

6.5

S4

down in down out wall mounted

SG600-022G-4T

SG600-030G-4T

175

435

265

130

420

6.5

S5

down in down out book type

SG600-037G-4T

SG600-045G-4T

 

265

 

670

 

358

 

200

 

645

 

9

S6

up in down out book type

SG600-055G-4T

SG600-075G-4T

SG600-090G-4T

 

305

 

845

 

358

 

200

 

820

 

11

 

S7

up in down out book type

SG600-110G-4T

SG600-132G-4T

 

Specifications    
POWER Input Voltage and frequency Single phase :220V 50/60Hz;                                                       Three phase: 220V 50/60Hz;                                                  Three phase 380V 50/60Hz
Allowed fluctuation range voltage unbalance rate:<3%; Frequency:±5%; aberration rate: as IEC61800-2 required
Switching impulse current Lower than rated current
Frequency drive efficiency ≥96%
POWER Output Output voltage Output under rated condition: 3 phase, 0~input voltage, deviation<5%
Output frequency range 0~1500Hz
Output frequency accuracy Max frequency ±0.5%
Overload capacity G type: 150% rated current/1 min, 180% rated current/2s, 200% rated current/0.5s
Power Level Single phase 220V 50/60Hz 0.75kW - 220kW
Three phase 220V 50/60Hz 0.75kW - 220kW
Three phase 380V 50/60Hz 0.75kW - 1,120kW
Three phase 690V 50/60Hz 0.75kW - 1,250kW
Main Control Performance Motor type Three-phase asynchronous motor;                                         Permanent magnet synchronous motor (sine wave)
Control mode V/F control, SVC, 
Carrier frequency 1.0~16.0kHz
Speed control range SVC : rated load 1:200
Steady speed SVC : ≤2% rated synchronized speed
Starting torque SVC : 150% rated torque at 0.5Hz
Torque response SVC :<20ms
Frequency accuracy Digital setting: max frequency×±0.01%; Analog setting: max frequency×±0.2%
Frequency resolution Digital setting: 0.01Hz; Analog setting: max frequency×0.05
Basic Functions Torque control Torque setting calculation, torque mode speed limit
DC braking capability Starting frequency:0.00~50.00Hz; Braking time:0.0~60.0s; Braking current:0.0~150.0% rated
Torque boost Automatic torque boost 0.0%~100.0%; Manual torque boost 0.0%~30.0%
V/F curve Four modes: linear torque characteristic curve, self-set V/F curve, torque reduction characteristic curve (1.1 to 2.0 power), square V/F curve
Acceleration/Deceler ation curve 2 modes: linear Acceleration/Deceleration and S curve Acceleration/Deceleration. 4 sets of ACC/DEC, time unit 0.01s selectable, longest time: 650.00s
Automatic voltage adjustment When the voltage fluctuates, the output voltage is automatically maintained
Automatic energy-saving operation Automatically optimize output voltage according to load in V/F control mode to achieve energy-saving operation
Rated output voltage Using the power supply voltage compensation function, the rated voltage of the motor is 100%, which can be set within the range of 50 to 100% (the output cannot exceed the input voltage).
Automatic current limit Automatically limit the current during operation to prevent frequent over-current fault trips
Voltage While power supply voltage fluctuates, it can auto-keep constant output voltage
Auto-limit current Auto-limit the current while running to prevent over current break trouble
Instant power off Uninterrupted operation through bus voltage control during instantaneous power loss
Standard functions PID control, speed track, power off restart, jump frequency, upper/lower frequency limit control, program operation, multi- speed, RS485, analog output, frequency impulse output
Frequency setting channels Keyboard digital setting, Analog voltage/current terminal AI1, Analog voltage/current terminal AI2, Communication given and multi-channel terminal selection, Main and auxiliary channel combination, expansion card, supporting different modes switch.
Feedback input channel Voltage/Current Terminal AI1, Voltage/Current Terminal AI12, Communication given, Low-speed pulse input PUL, extension card
Running command  Operation panel given, external terminal given, communication given, expansion card given
Input command signal Start, stop, FWD/REV, JOG, multi-step speed, free stop, reset, ACC/DEC time selection, frequency given channel selection, external fault alarm
External output signal 1 relay output, 1 collector output, 1 AO output: 0~10V output or 4~20mA output
Protective Functions Protective function Overvoltage, under-voltage, current limit, over-current, overload, electric thermal relay, overheat, overvoltage stall, data protection, rapid speed protection, input/output phase failure protection.
Keyboard Display LED display Built-in keyboard: single line 5- digital tube display, monitor 1 drive status quantity
Status monitor Output frequency, given frequency, output current, input voltage, output voltage, motor speed, PID feedback, PID given value, module temperature etc. monitor parameters
Error alarm Over-voltage, under-voltage, over-current, short circuit, phase failure, overload, overheat, overvoltage stall, current limit, or current fault health, historical fault record.
Surroundings Install place The altitude is less than 1000 meters, and the derating is more than 1000 meters. The derating is 1% for every 100 meters. 
Temperature and humidity -10 ~ +50°C, derating can be used above 40 °C, the maximum temperature is 60 °C (no-load operation), 5%~95%RH(no condensation)
Vibration 5.9m/s2(0.6g)
Storage temperature -30~+60℃
Installation mode Wall hanging
Protection degree IP20
Cooling method Forced air cooling



Previous: SG600 0.75-4kW