en
Solar pump inverter
Solar pump inverter

Solar pump inverter

MOQ: 100 Pieces
Delivery time: 15 Day
1.Excellent MPPT algorithm: high efficiency, small DC bus voltage fluctuation, stable output frequency. 2.It can drive asynchronous motors and permanent magnet synchronous motors. 3.A variety of special protections: low voltage protection, low frequency protection, dry protection, too little power protection, high current protection, float protection, these protections can be automatically reset.
4.AC and DC input adaptive operation, photovoltaic works when the light is strong, and photovoltaic and AC work at the same time when the light is weak. 5. Multi-point power-flow curve, which can realize simple flow metering.
Product Details

The user can learn the specification from the nameplate. SG600 -2K2G- 4T

                              

 

Mark

Description

Contents

Series models

SG350,old series   SG600,new series

Drive power

7K5G stand for 7.5kw, submersible pump type     1K5G stands for 1.5kw, submersible pumps type

Voltage specification

1: = 80 to 350V DC or 110 to 220V AC input

2: = 230 to 450V DC or 200 to 240V AC   input

4: = 350 to 900V DC or 380 to 480V AC   input

S:    1 phase    input

T:    three phase input

 

3.5.Solar pump drive technical specification

 

Recommended MPPT voltage range

230~450VDC for 220VAC/240V pumps with 0.75Kw to 4kw 350~800VDC, for 380VAC pumps with1.5kw to 450kw

Recommended input voltage

310Vmp DC for 220V AC pumps, 540Vmp DC for 380V AC pumps

Motor type

Control for permanent magnet synchronous motor and asynchronous motor pumps

Maximum DC power input

1. 450VDC for 220AC output      

 2. 800VDC or 900VDC for 380V AC output

Rated output voltage

1 phase, 220V.       3 phase, 220V/380V/440V

Output frequency range

0~400Hz

MPPT efficiency

99%,

Ambient temperature range

-10~+50 C

Solar pump control special performance

MPPT ( maximum power point tracking), CVT (constant voltage

tracking), auto/manual operation, dry run protection, low stop frequency protection, minimum power input, motor maximum

current protection, flow calculating, energy generated calculating and water tank level detected, etc

Protection function

Stall protection, phase loss protection, phase short circuit

protection , ground to phase short circuit protection , input and    output short circuit protection, over-temperature protection, etc

Protection degree

IP20, Air force cooling

Running mode

MPPT or CVT

Altitude

Below 1000m; above 1000m, derated 1% for every additional 100m.

Standard

AC input backup circuit

CE, Design based on vector control drive, more specification please refer to vector control drive operation manual

 

 

 

 

 

 

 

3.6. Models and specification

SN

Models

Rate

current

(A)

DC input range    (VDC)

Output voltage  (VAC)

Applicable

for pumps

(KW)

Recommen

ded VOC

(VDC)

shape and size

1

SG600-0K7G-2S

4.0A

230 to 450

220 to 240

0.75KW

360 to 400

Fig.A

2

SG600-1K5G-2S

7.5A

230 to 450

220 to 240

1.5KW

360 to 400

Fig.A

3

SG600-2K2G-2S

10A

230 to 450

220 to 240

2.2KW

360 to 400

Fig.A

4

SG600-3K0G-2S

13.5A

230 to 450

220 to 240

3.0KW

360 to 400

Fig.B

5

SG600-4K0G-2S

16A

230 to 450

220 to 240

4.0KW

360 to 400

Fig.B

6

SG600-0K7GB-4T

2.5A

350 to 800

380 to 440

0.75KW

650 to700

Fig.A

7

SG600-1K5GB-4T

3.7A

350 to 800

380 to 440

1.5KW

650 to700

Fig.A

8

SG600-2K2GB-4T

5.0A

350 to 800

380 to 440

2.2KW

650 to700

Fig.A

9

SG600-4K0GB-4T

10A

350 to 800

380 to 440

4.0KW

650 to700

Fig.A

10

SG600-5K5GB-4T

13A

350 to 800

380 to 440

5.5KW

650 to700

Fig.B

11

SG600-7K5GB-4T

17A

350 to 800

380 to440

7.5KW

650 to700

Fig.B

12

SG600-011GB-4T

25A

350 to 800

380 to 440

11KW

650 to700

Fig.C

13

SG600-015GB-4T

33A

350 to 800

380 to 440

15KW

650 to700

Fig.C

14

SG600-018G-4T

38A

350 to 800

380 to 440

18.5KW

650 to700

Fig.C

15

SG600-022G-4T

45A

350 to 800

380 to 440

22KW

650 to700

Fig.C

16

SG600-030G-4T

60A

350 to 800

380 to 440

30KW

650 to700

Fig.C

17

SG600-037G-4T

75A

350 to 800

380 to 440

37KW

650 to700

Fig.C

18

SG600-045G-4T

91A

350 to 800

380 to 440

45KW

650 to700

Fig.C

19

SG600-055G-4T

110A

350 to 800

380 to 440

55KW

650 to700

Fig.C

20

SG600-075G-4T

150A

350 to 800

380 to 440

75KW

650 to700

Fig.C

21

SG600-090G-4T

180A

350 to 800

380 to 440

90KW

650 to700

Fig.C

22

SG600-110G-4T

210A

350 to 800

380 to 440

110KW

650 to700

Fig.C

23

SG600-132G-4T

250A

350 to 800

380 to 440

132KW

650 to700

Fig.C

 

Dimensions Hole Diagram

 

 

VFD specifications and models

Dimension ( mm )

Mounting holes size ( mm )

Mountin

g holes (mm)

 

Fig

 

Remark

W

H

D

W1

H1

d

Fig

Wiring

1 PHASE 2S 220V

SG600-0K75G-2S

 

86

 

187

 

152

 

68

 

176

 

5.5

 

A

down in down out wall mounted

SG600-1K5G-2S

SG600-2K2G-2S

SG600-3K0G-2S

105

265

164

87

252

6

B

down in down out wall mounted

SG600-4K0G-2S

3 PHASE 4T 380V

SG600-0K75GB-4T

 

86

 

187

 

152

 

68

 

176

 

5.5

 

A

down in down out wall mounted

SG600-1K5GB-4T

SG600-2K2GB-4T

SG600-4K0GB-4T

SG600-5K5GB-4T

105

265

164

87

252

6

B

down in down out wall mounted

SG600-7K5GB-4T

SG600-011GB-4T

150

333

216

100

314

5.5

C

down in down out wall mounted

SG600-015GB-4T

SG600-018G-4T

180

383

228

120

363

6.5

C

down in down out wall mounted

SG600-022G-4T

SG600-030G-4T

175

435

265

130

420

6.5

C

down in down out book type

SG600-037G-4T

SG600-045G-4T

 

265

 

670

 

358

 

200

 

645

 

9

C

up in down out book type

SG600-055G-4T

SG600-075G-4T

SG600-090G-4T

 

305

 

845

 

358

 

200

 

820

 

11

 

C

up in down out book type

SG600-110G-4T

SG600-132G-4T